MGIMS WARDHA MGIMS WARDHA Solved Paper-2011

  • question_answer
    The sensitiveness of a moving coil galvanometer can be increased by decreasing the

    A)  number of turns in the coils

    B)  are of the coil

    C)  magnetic field

    D)  couple per unit twist of the suspension

    Correct Answer: D

    Solution :

                     For moving coil galvanometer  \[C\theta =niBA\]where C = Couple per twist of the suspension \[\theta =\] deflection of galvanometer \[\frac{\theta }{i}=\frac{nBA}{C}\] Sensitivity of galvanometer \[=\frac{nBA}{C}\] \[\therefore \]To increase the sensitivity of galvanometer, value of C should be decreased.